1How the results reach Seal.
In the laboratory
Particle Measuring Systems particle counters
- FacilityPro
- SamplerSight Pharma
- DataAnalyst
- and 2 more
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Location and sample
- ≥0.5 µm
- ≥5.0 µm
- Volume
- Original file, kept
Results from the Particle Measuring Systems particle counters come from FacilityPro, SamplerSight Pharma or DataAnalyst, among 5 applications.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in FacilityPro, SamplerSight Pharma or DataAnalyst: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- FacilityPro
- 14 models: particle counters and air samplers.
- DataAnalyst
- 3 models: particle counters and air samplers.
- SamplerSight Pharma
- 3 models: particle counters.
- FacilityNet
- 2 models: particle counters.
- SamplerSight
- 2 models: particle counters.
Saved by the instrument
- HandiLaz Mini II
- 1 model: particle counter. Saves data to an SD card or USB drive.
- Lasair III
- 1 model: particle counter. Saves CSV files to a USB drive.
- Lasair III 110
- 1 model: particle counter. Saves CSV files over USB.
3The Particle Measuring Systems models.
These are Particle Measuring Systems instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Particle counters
Particle counts per size channel for each sample volume and location, against the limits set.
- AirNet II 201-4
- AirNet II 301-4
- AirNet II 310-4
- AirNet II 501-4
- AirNet II 510
- AirNet II 510 XR
- AirNet II 510-4
- APSS-2000
- HandiLaz Mini II
- IsoAir 310P
- IsoAir Pro-E
- IsoAir Pro-Plus
Show all 22 models
- Lasair EZ
- Lasair II
- Lasair III
- Lasair III 110
- Lasair Pro
- LiQuilaz II E
- LiQuilaz II S
- NanoAir 10
- SLS-20
- SLS-1040
Air samplers
The volume of air drawn onto each plate, with its location and time; the colony count is read after incubation.
- MiniCapt Mobile
- MiniCapt Pro-E 25
- MiniCapt Pro-Plus 25
- MiniCapt Pro-Plus 100
- MiniCapt Remote
4Where the results go next.
Blueprints
- Environmental monitoring →
Link environmental results to locations, operations and investigations.
- Contamination control →
Connect contamination risks to controls and evidence of performance.
- Microbiology laboratory →
Track plates, organisms and results back to samples and batches.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Particle Measuring Systems instruments.