Skip to main content

MVE Biological Solutions instruments in Seal

Seal Edge collects the files MVE Biological Solutions software saves and sends each original to Seal, linked to its sample, method and run.

MVE Biological Solutions instruments to SealInstrument export

Seal reads
Exports from TEC Connect and CryoVerse
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

MVE Biological Solutions freezers

  • TEC ConnectSaves the controller’s event log as CSV
  • CryoVerse

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Storage unit

  • Temperature
  • Set point
  • Alarm
  • Original file, kept
How a result from the MVE Biological Solutions freezers reaches Seal.

Results from the MVE Biological Solutions freezers come from TEC Connect or CryoVerse.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in TEC Connect or CryoVerse: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

TEC Connect
26 models: freezers. Saves the controller’s event log as CSV.
CryoVerse
5 models: freezers.

Saved by the instrument

Freezers
6 models. Each saves the event log as CSV to a USB drive.

3The MVE Biological Solutions models.

These are MVE Biological Solutions instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Freezers

Cabinet temperature over time and alarm events, from the unit’s own log or a monitoring system.

  • Fusion
  • Fusion 800
  • HE 800 C
  • HE 815P-190
  • HE 819P-190
  • HE 1536P-190
  • HE 1539P-190
  • HE 1542R-190
  • HE 1879P-190
  • HE 1881R-190
  • HE 1892P-190
  • HE 1894R-190
  • Show all 36 models
  • HEco 815P-190
  • HEco 818P-190
  • HEco 819P-190
  • HEco 1536P-190
  • HEco 1539P-190
  • HEco 1542R-190
  • HEco 1879P-190
  • HEco 1881R-190
  • HEco 1892P-190
  • HEco 1894R-190
  • MVE 103
  • MVE 205
  • MVE 510
  • MVE 616
  • MVE 816P-2T-190
  • MVE 1426
  • MVE 1839
  • MVE 1842P-150
  • MVE 1877P-2T-150
  • Vario 1536P
  • Vario 1539R
  • Vario 1879P
  • Vario 1881R
  • Vario 1894R

4Where the results go next.

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your MVE Biological Solutions instruments.

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.