Molecular Devices instrument integration

Molecular Devices integration joins SoftMax Pro plate-reader assays with MetaXpress imaging. The vendor applications still acquire and analyse.

Illustration of a seal beside a Molecular Devices SpectraMax iD5 plate reader.

Molecular Devices instruments to SealInstrument export

Seal reads
Exports from CellReporterXpress, MetaXpress and 4 more
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1Choose the source software and evidence.

Each route starts from a documented output of the vendor software. Check the installed version, licensed options and export settings against the linked docs. A listed route is not an acquisition driver or a universal parser.

Molecular Devices SoftMax Pro connection overview →

Text, Excel or XML exports; select raw, reduced or both plate data.

One plate assay with source files and selected sample results linked to the experiment. Create well records only if the workflow needs individual tracking.

Molecular Devices ImageXpress MetaXpress connection overview →

MetaXpress measurement text or Excel exports and separately retained source images.

One sample-well phenotype analysis with selected metrics; keep cell-level tables as files unless individual objects need review.

2Choose raw, reduced or image-derived results deliberately.

SoftMax Pro exports can include raw plate data, reduced results or both. Identify whether the receiving workflow needs the measured signal, a calculated concentration or another evaluated result. Retain the assay definitions and report needed to understand transformations such as blank correction, dilution or a standard-curve calculation.

MetaXpress measurement exports need the analysis settings and image context that produced them. Decide whether the receiving record represents a well summary, a field of view or another observation level supported by the export. Keep images separately identifiable where they are required to review the measured feature or classification.

3Use a shared sample map without flattening the evidence.

Resolve the plate first, then the well and sample assignment. The same well address can recur across plates and experiments. Preserve controls, standards and replicate relationships rather than importing every row as an unrelated sample. If a plate layout was revised, retain the version used for the analysis.

Keep channel, time-point and feature dimensions where they are part of the measurement. A plate-reader kinetic trace is not a single endpoint, and an image-derived cell feature is not automatically comparable with an assay concentration. The sample reference joins the workflows while the result records preserve their method-specific meaning.

4Check result exclusions and analytical revisions.

An excluded replicate or rejected image field should remain visible in the interpretation of a summary. Choose destination fields that can preserve reported qualifiers and missing-data states. Avoid converting an unavailable result into zero merely to make a numeric field accept the import.

Reanalysis can change reduced plate results or image-derived measurements without changing the original acquisition. Test how the Script identifies a revised result and preserves the earlier evidence. Confirm the mapping again when the assay template, image-analysis settings or export layout changes.

5Example: relate a plate assay to imaging observations

The joined record supports a comparison without implying that the two analyses measure the same property.

Plate and samples
Preserve the plate identity, well assignments and relevant layout revision.
Plate assay
Link the SoftMax Pro source data and the selected raw or reduced result.
Imaging
Link the MetaXpress measurement, analysis context and supporting image evidence.

Use these relationships as a mapping example for your own templates. The receiving fields and record grain are configured through Seal Scripts and APIs.

6Configure the collection and mapping for your site.

In the laboratory

Molecular Devices instruments

  • SoftMax ProSaves text, Excel or XML exports
  • ImageXpress MetaXpressSaves MetaXpress measurement text or Excel exports

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Plate and sample

  • Well
  • Reading
  • Concentration
  • Original file, kept
How a result from Molecular Devices software reaches Seal.

For local exports, use a completed-file handoff on the instrument workstation or another approved site computer. Seal Edge collects the file and uploads it to the chosen Seal destination over outbound HTTPS. Keep source files until delivery and mapping have been verified.

A Seal Script can validate the expected layout, resolve source identities and write selected typed fields. Keep the original export as File content. Acquisition and vendor analysis remain in the source application; Seal collects the completed results and does not send instructions to the instrument.

Follow the on-site equipment setup instructions, then use the source-specific guide above to test the actual export and mapping. For a result exchange with an existing LIMS, also define that system’s supported receiving operation and sample identifiers.

7Test the configured workflow with known evidence.

  1. Use a plate with standards, controls and a known sample to verify well and result assignments.
  2. Compare a reduced result with its underlying data and a selected image feature with its source analysis.
  3. Test an excluded replicate and a revised analysis so neither is mistaken for an ordinary new measurement.

Keep the test outcome with the configuration and repeat the relevant checks when software, reports, analysis settings or destination fields change.

Discuss your Molecular Devices workflow with a representative export, the installed software version and the records you want to connect.

8The Molecular Devices models.

These are Molecular Devices instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed works the same way if its software saves a file.

Plate readers

A value for each well (absorbance, fluorescence or luminescence), often reduced to concentrations against a standard curve.

  • Analyst
  • EMax Endpoint
  • EMax Plus
  • FilterMax F3
  • FilterMax F5
  • FlexStation 3
  • FLIPR Penta
  • FLIPR Tetra
  • Gemini EM
  • Gemini XPS
  • SpectraMax 190
  • SpectraMax 340PC384
  • SpectraMax ABS
  • SpectraMax ABS Plus
  • SpectraMax i3
  • SpectraMax i3x
  • SpectraMax iD3
  • SpectraMax iD3s
  • SpectraMax iD5
  • SpectraMax iD5e
  • SpectraMax M2
  • SpectraMax M2e
  • SpectraMax M3
  • SpectraMax M4
  • SpectraMax M5
  • SpectraMax M5e
  • SpectraMax Mini
  • SpectraMax Paradigm
  • SpectraMax Plus 384
  • VersaMax
  • VMax Kinetic

High-content imaging systems

Images of each well and field, analysed into measurements per cell or per well.

  • ImageXpress Confocal HT.ai
  • ImageXpress HCS.ai High-Content Screening System
  • ImageXpress Micro 4
  • ImageXpress Micro Confocal
  • ImageXpress Nano Automated Imaging System
  • ImageXpress Pico Automated Cell Imaging System

Colony pickers

Which colonies or clones were picked, from which plate and position, into which destination well.

  • ClonePix 2 Mammalian Colony Picker
  • QPix 400 Series Microbial Colony Picker
  • QPix FLEX
  • QPix HT
  • QPix XE Mammalian Colony Screening

Cell analyzers

  • Axon Axoclamp 900A Amplifier
  • Axon Axopatch 200B Amplifier
  • Axon MultiClamp 700B Amplifier
  • FLIPR Penta High-Throughput Cellular Screening System

Microplate washers

Runs the wash steps between assay stages; it measures nothing itself, so the result comes from the reader.

  • AquaMax 2000
  • AquaMax 4000
  • MultiWash+

Imaging systems

Images with their acquisition settings, and measurements where analysis software takes them.

  • CloneSelect Imager
  • CloneSelect Imager FL

Cell culture systems

  • CellXpress.ai Automated Cell Culture System

Luminometers

Light output (RLU) for each sample or well.

  • SpectraMax L

Microvolume spectrophotometers

Absorbance converted to nucleic acid or protein concentration, with purity ratios such as A260/A280.

  • SpectraMax QuickDrop

Other

  • CloneSelect Single-Cell Printer