Seal Edge collects the files Knauer software saves and sends each original to Seal, linked to its sample, method and run.

Knauer instruments to SealInstrument export

Seal reads
Exports from EuroOsmo 7400
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Knauer HPLC / UHPLC systems

  • ClaritySaves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf)
  • Chromeleon CDSSaves report exports selected in the installed Chromeleon version

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Sample and injection

  • Retention time
  • Peak area
  • Amount
  • Original file, kept
How a result from the Knauer HPLC / UHPLC systems reaches Seal.

Results from the Knauer HPLC / UHPLC systems come from Clarity or Chromeleon CDS.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in Clarity or Chromeleon CDS: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

EuroOsmo 7400
1 model: osmometer.
ClarityDataApex
51 models: LC detectors, LC pumps, LC autosamplers, HPLC / UHPLC systems, column ovens and fraction collectors. Saves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf).
Chromeleon CDSThermo Fisher Scientific
6 models: LC detectors, LC autosamplers, column ovens and LC pumps. Saves report exports selected in the installed Chromeleon version.

3The Knauer models.

These are Knauer instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

LC detectors

The detector’s signal over time is the chromatogram; the chromatography data system integrates its peaks into retention times, areas and amounts.

  • AZURA CM 2.1S Detector
  • AZURA DAD 2.1L
  • AZURA DAD 6.1L
  • AZURA FLD 2.1L Detector
  • AZURA MWD 2.1L
  • AZURA RID 2.1L Detector
  • AZURA UVD 2.1L Detector
  • AZURA UVD 2.1S Detector
  • AZURA VWD 2.1L Detector
  • BlueShadow 10D Detector
  • BlueShadow 40D Detector
  • BlueShadow 50D Detector
  • Show all 25 models
  • K-2600 Detector
  • K-2700 Detector
  • K-2800 Detector
  • PLATINblue MW-1 Detector
  • PLATINblue PDA-1 Detector
  • S2300 RID Detector
  • S2400 RID Detector
  • S2520 VWD Detector
  • S2550 VWD Detector
  • S2800 PDA Detector
  • S2850 PDA Detector
  • Smartline S2500 VWD Detector
  • Smartline S2600 MWD Detector

LC pumps

Flow, solvent composition and pressure, recorded by the chromatography data system with each injection; the results come from the detector.

  • AZURA P 2.1L Pump
  • AZURA P 2.1S Pump
  • AZURA P 4.1S Pump
  • AZURA P 6.1L
  • AZURA P 8.1L Pump
  • BlueShadow 40P Pump
  • BlueShadow 80P Pump
  • K-120 Pump
  • K-500 Pump
  • K-501 Pump
  • K-1001 Pump
  • K-1800 Pump
  • PLATINblue P-1 Pump
  • Smartline 1050 Pump
  • Smartline S1000 Pump

LC autosamplers

Which vial and volume each injection took, recorded with its chromatogram so each result keeps its sample.

  • AS 8.1L Autosampler
  • AS 3800 Autosampler
  • AS 3900 Autosampler
  • AS 3950 Autosampler
  • AZURA AS 6.1L
  • Optimas Autosampler
  • PLATINblue AS-1 Autosampler

Column ovens

The column temperature, set in the method and recorded with each injection.

  • AZURA CT 2.1
  • JetStream Column Oven
  • PLATINblue T-1 Column Oven
  • S4000 Column Oven
  • S4050 Column Oven

HPLC / UHPLC systems

A chromatogram for each injection, integrated into peaks with retention times, areas and amounts, and reported per sample in a sequence.

  • AZURA HPLC
  • BlueShadow HPLC
  • Smartline HPLC
  • WellChrom HPLC

Fraction collectors

Where each fraction went and the part of the chromatogram it was collected from.

  • FC 6.1 Fraction Collector

Osmometers

Osmolality for each sample, in mOsm/kg.

  • Osmometer K-7400S

4Where the results go next.

Connection guides

Blueprints

5Start with one instrument.