1The Knauer models.
These are Knauer instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
LC detectors
- AZURA CM 2.1S Detector
- AZURA DAD 2.1L
- AZURA DAD 6.1L
- AZURA FLD 2.1L Detector
- AZURA MWD 2.1L
- AZURA RID 2.1L Detector
- AZURA UVD 2.1L Detector
- AZURA UVD 2.1S Detector
- AZURA VWD 2.1L Detector
- BlueShadow 10D Detector
- BlueShadow 40D Detector
- BlueShadow 50D Detector
- K-2600 Detector
- K-2700 Detector
- K-2800 Detector
- PLATINblue MW-1 Detector
- PLATINblue PDA-1 Detector
- S2300 RID Detector
- S2400 RID Detector
- S2520 VWD Detector
- S2550 VWD Detector
- S2800 PDA Detector
- S2850 PDA Detector
- Smartline S2500 VWD Detector
- Smartline S2600 MWD Detector
LC pumps
- AZURA P 2.1L Pump
- AZURA P 2.1S Pump
- AZURA P 4.1S Pump
- AZURA P 6.1L
- AZURA P 8.1L Pump
- BlueShadow 40P Pump
- BlueShadow 80P Pump
- K-120 Pump
- K-500 Pump
- K-501 Pump
- K-1001 Pump
- K-1800 Pump
- PLATINblue P-1 Pump
- Smartline 1050 Pump
- Smartline S1000 Pump
LC autosamplers
- AS 8.1L Autosampler
- AS 3800 Autosampler
- AS 3900 Autosampler
- AS 3950 Autosampler
- AZURA AS 6.1L
- Optimas Autosampler
- PLATINblue AS-1 Autosampler
Column ovens
- AZURA CT 2.1
- JetStream Column Oven
- PLATINblue T-1 Column Oven
- S4000 Column Oven
- S4050 Column Oven
HPLC / UHPLC systems
- AZURA HPLC
- BlueShadow HPLC
- Smartline HPLC
- WellChrom HPLC
Osmometers
- Osmometer K-7400S
Other
- FC 6.1 Fraction Collector
2How Seal collects the results.
Seal IoT runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. For these instruments that is usually Chromeleon CDS and Clarity. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the run and sample it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and the vendor’s analysis stay in the instrument software: Seal collects completed results and sends no instructions to the instrument.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
3Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Knauer instruments.
