1How the results reach Seal.
In the laboratory
JASCO HPLC / UHPLC systems
- ClaritySaves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf)
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and injection
- Retention time
- Peak area
- Amount
- Original file, kept
Results from the JASCO HPLC / UHPLC systems come from Clarity.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in Clarity: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- Spectra Manager
- 35 models: FTIR spectrometers, UV-Vis spectrophotometers, Raman spectrometers, spectrofluorometers and circular dichroism spectrometers. Saves X/Y text, CSV and JCAMP (.dx) files.
- ClarityDataApex
- 17 models: LC detectors and LC pumps. Saves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf).
3The JASCO models.
These are JASCO instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
LC detectors
The detector’s signal over time is the chromatogram; the chromatography data system integrates its peaks into retention times, areas and amounts.
- CD-1595 Detector
- CD-2095 Detector
- CD-4095 Detector
- CL-2027 Detector
- FP-821 Detector
- FP-920 Detector
- FP-2020 Detector
- FP-2025 Detector
- FP-4020 Detector
- FP-4025 Detector
- OR-2090 Detector
- RI-2031 Detector
- UV-975 Detector
- UV-1575 Detector
- UV-2070 Detector
- UV-2077 Detector
UV-Vis spectrophotometers
Absorbance at set wavelengths or across a spectrum, converted to concentration where a method applies.
- MSV-5200
- MSV-5500
- MSV-5700
- V-630
- V-670
- V-730
- V-750
- V-760
- V-770
- V-780
FTIR spectrometers
An infrared spectrum, with an identity or a quantity where a library or method is applied.
- FT/IR-4X
- FT/IR-6X
- FT/IR-8X
- IRT-5X
- IRT-7X
- IRT-1000X
- VIR-100
- VIR-200
- VIR-300
Raman spectrometers
A Raman spectrum, with an identity or a concentration where a library or model is applied.
- NRS-4500
- NRS-5000 Series
- NRS-7000 Series
- PR-1w
- RMP-510
- RMP-520
- RMP-530
Circular dichroism spectrometers
A circular dichroism spectrum, read for secondary structure, or followed against temperature for stability.
- High-Throughput Circular Dichroism System (HTCD)
- J-810
- J-820
- J-1100
- J-1500
- J-1700
Spectrofluorometers
Fluorescence emission and excitation spectra, or intensities at set wavelengths.
- FP-8250
- FP-8300
- FP-8350
- FP-8500
- FP-8550
- FP-8650
LC pumps
Flow, solvent composition and pressure, recorded by the chromatography data system with each injection; the results come from the detector.
- PU-880 Pump
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- Scientific data →
Keep instrument files and metadata connected to laboratory work.
- Raw material release →
Connect receipt, sampling and testing before material use.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your JASCO instruments.