1How the results reach Seal.
In the laboratory
Gilson HPLC / UHPLC systems
- Chromeleon CDSSaves report exports selected in the installed Chromeleon version
- ClaritySaves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf)
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and injection
- Retention time
- Peak area
- Amount
- Original file, kept
Results from the Gilson HPLC / UHPLC systems come from Chromeleon CDS or Clarity.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in Chromeleon CDS or Clarity: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- Chromeleon CDSThermo Fisher Scientific
- 14 models: LC autosamplers, LC detectors and LC pumps. Saves report exports selected in the installed Chromeleon version.
- ClarityDataApex
- 11 models: LC pumps, LC detectors and fraction collectors. Saves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf).
3The Gilson models.
These are Gilson instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
LC pumps
Flow, solvent composition and pressure, recorded by the chromatography data system with each injection; the results come from the detector.
- 302 Pump
- 303 Pump
- 305 Pump
- 306 Pump
- 307 Pump
- 331 Pump
- 332 Pump
- 333 Pump
- 334 Pump
LC detectors
The detector’s signal over time is the chromatogram; the chromatography data system integrates its peaks into retention times, areas and amounts.
- 112 Detector
- 151 UV/VIS Detector
- 152 UV/VIS Detector
- 155 UV/VIS Detector
- 156 UV/VIS Detector
- 157 Detector
- 159 Detector
- PrepELS II Detector
LC autosamplers
Which vial and volume each injection took, recorded with its chromatogram so each result keeps its sample.
- 215 Liquid Handler
- 221XL Autosampler
- 222XL Autosampler
- 231XL Autosampler
- 232XL Autosampler
- 233XL Autosampler
Fraction collectors
Where each fraction went and the part of the chromatogram it was collected from.
- FC 203B Fraction Collector
- FC 204 Fraction Collector
Liquid handlers
A record of what moved where: source and destination labware and wells, volumes and any errors in each run.
- PIPETMAX 278
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Scientific data →
Keep instrument files and metadata connected to laboratory work.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- Downstream process development →
Compare chromatography runs, fraction assays and filtration studies.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Gilson instruments.