1How the results reach Seal.
In the laboratory
Bruker FTIR spectrometers
- OPUSSaves OPUS ASCII or JCAMP spectral exports
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and measurement
- Spectrum
- Library match
- Result
- Original file, kept
Results from the Bruker FTIR spectrometers come from OPUS.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in OPUS: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- OPUS
- 11 models: FTIR spectrometers, Raman spectrometers and NIR spectrometers. Saves OPUS ASCII or JCAMP spectral exports.
- TopSpin
- 4 models: NMR spectrometers.
- BioPharma Compass
- 2 models: mass spectrometers.
- MBT Compass HT
- 2 models: microbial detection systems.
- SCiLS Lab
- 2 models: mass spectrometers.
- IconNMR
- 1 model: NMR spectrometer.
- ProteoScape
- 1 model: LC-MS system.
- Sierra SPR control software
- 1 model: surface plasmon resonance system.
3The Bruker models.
These are Bruker instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
FTIR spectrometers
An infrared spectrum, with an identity or a quantity where a library or method is applied.
- ALPHA II
- CONFOCHECK
- HTS-XT
- HYPERION II
- IFS 125HR
- INVENIO
- LUMOS II
- MATRIX-MF II
- MOBILE-IR II
- VERTERA
- VERTEX NEO
LC-MS systems
Chromatograms with mass spectra, processed into amounts of target compounds or the masses and identities of what was found.
- compact
- EVOQ DART-TQ+
- impact II VIP
- timsMetabo
- timsOmni
- timsOmni Sigma
- timsTOF fleX
- timsTOF fleX MALDI-2
- timsTOF HT
- timsTOF Pro 2
- timsUltra AIP
Mass spectrometers
Mass spectra, processed into identified compounds or quantified amounts.
- autoflex maX
- microflex LRF
- neofleX
- rapifleX
- scimaX
- smartfleX
- solariX
- timsMRMS
- ultrafleXtreme
Surface plasmon resonance systems
Sensorgrams of binding over time, fitted to association and dissociation rates and affinity (KD).
- MASS-1
- MASS-2
- Sierra SPR-24 Pro
- Sierra SPR-32 Pro
- SPR-2
- SPR-2-MK2
- SPR-4
NMR spectrometers
NMR spectra, used to confirm structure and, with a reference, to measure content.
- AVANCE NEO
- AVANCE NEO NanoBay
- AVANCE NEO-X
- AvanceCore
- Fourier 80
NIR spectrometers
A near-infrared spectrum, with an identity or a content where a model is applied.
- BEAM
- MATRIX-F II
- MPA III
- TANGO II
Raman spectrometers
A Raman spectrum, with an identity or a concentration where a library or model is applied.
- BRAVO
- HyperFlux PRO Plus
- RAM II
- SENTERRA II
Cell analyzers
- Beacon Discovery Optofluidic System
- IsoLight System
- IsoSpark
GC-MS systems
A chromatogram with a mass spectrum for each scan, processed into identified compounds and their amounts.
- ecTOF
- EVOQ GC-TQ
Microbial detection systems
- MALDI Biotyper sirius
- MALDI Biotyper sirius one
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- Scientific data →
Keep instrument files and metadata connected to laboratory work.
- Raw material release →
Connect receipt, sampling and testing before material use.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Bruker instruments.