1How the results reach Seal.
In the laboratory
BINDER incubators
- APT-COM 4Saves PDF, HTML and CSV reports
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Chamber
- Temperature
- Set point
- Alarm
- Original file, kept
Results from the BINDER incubators come from APT-COM 4.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in APT-COM 4: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- APT-COM 4
- 56 models: incubators, climate chambers and freezers. Saves PDF, HTML and CSV reports.
Saved by the instrument
- Incubators, climate chambers and freezers
- 40 models. Each saves the data logger’s readings over USB, in an open format.
- Incubators
- 11 models. Each saves recorded data over USB.
3The BINDER models.
These are BINDER instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Incubators
Chamber temperature over time, with carbon dioxide and humidity where they are controlled, and alarm events.
- BD 23
- BD 56
- BD 115
- BD 260
- BD 400
- BD 720
- BD-S 56
- BD-S 115
- BF 56
- BF 115
- BF 260
- BF 400
Show all 39 models
- BF 720
- CB 56
- CB 170
- CB 260
- CB-S 170
- CB-S 260
- CBF 170
- CBF 260
- KB 65
- KB 130
- KB 260
- KB 470
- KB 720
- KB 1060
- KB ECO 240
- KB ECO 400
- KB ECO 720
- KB ECO 1020
- KB PRO 130
- KB PRO 260
- KB PRO 470
- KB PRO 720
- KB PRO 1060
- KB PRO 1600
- KT 53
- KT 115
- KT 170
Climate chambers
Chamber temperature and humidity over time, the conditions a stability study depends on.
- KBF 130
- KBF 260
- KBF 470
- KBF 720
- KBF 1060
- KBF 1600
- KBF PRO 130
- KBF PRO 260
- KBF PRO 470
- KBF PRO 720
- KBF PRO 1060
- KBF PRO 1600
- KBF-S ECO 240
- KBF-S ECO 400
- KBF-S ECO 720
- KBF-S ECO 1020
Freezers
Cabinet temperature over time and alarm events, from the unit’s own log or a monitoring system.
- UF V 350
- UF V 500
- UF V 700
4Where the results go next.
Blueprints
- Equipment lifecycle →
Connect equipment use, maintenance, calibration and qualification.
- Electronic logbooks →
Record equipment and facility events in their operational context.
- Stability studies →
Plan pulls and review results against study conditions and limits.
- Sample management →
Trace sample identity, custody, storage and use.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your BINDER instruments.