Waters Wyatt instruments in Seal

Seal Edge collects the files Waters Wyatt software saves and sends each original to Seal, linked to its sample, method and run.

Illustration of a seal beside a Wyatt DAWN multi-angle light scattering detector.

Waters Wyatt instruments to SealInstrument export

Seal reads
Exports from ASTRA, DYNAMICS and 2 more
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Waters Wyatt light scattering instruments

  • ASTRASaves ASTRA text exports of selected data and result tables
  • DYNAMICSSaves exported result tables and CSV data underlying graphs
  • CALYPSO

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Sample and measurement

  • Z-average
  • PDI
  • Molar mass
  • Original file, kept
How a result from the Waters Wyatt light scattering instruments reaches Seal.

Results from the Waters Wyatt light scattering instruments come from ASTRA, DYNAMICS or CALYPSO.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in ASTRA, DYNAMICS or CALYPSO: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

ASTRA
18 models: light scattering instruments and LC detectors. Saves ASTRA text exports of selected data and result tables.
DYNAMICS
7 models: light scattering instruments and zeta potential analyzers. Saves exported result tables and CSV data underlying graphs.
VISION
4 models: field-flow fractionation systems.
CALYPSO
1 model: light scattering instrument.

3The Waters Wyatt models.

These are Waters Wyatt instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Light scattering instruments

Size and polydispersity from dynamic light scattering, or molar mass from static and multi-angle light scattering.

  • Calypso II
  • DAWN
  • DAWN HELEOS
  • DAWN HELEOS II
  • DynaPro NanoStar
  • DynaPro NanoStar II
  • DynaPro Plate Reader 4
  • DynaPro Plate Reader II
  • DynaPro Plate Reader III
  • microDAWN
  • miniDAWN
  • miniDAWN TREOS
  • miniDAWN TREOS II
  • omniDAWN
  • ultraDAWN

LC detectors

The detector’s signal over time is the chromatogram; the chromatography data system integrates its peaks into retention times, areas and amounts.

  • microOptilab
  • microViscoStar
  • Optilab
  • Optilab rEX
  • Optilab T-rEX
  • Optilab UT-rEX
  • ViscoStar
  • ViscoStar II
  • ViscoStar III

Field-flow fractionation systems

Separates particles or molecules by size; the results come from its detectors, often light scattering.

  • Eclipse
  • Eclipse 3+
  • Eclipse AF4
  • Eclipse DualTec

Zeta potential analyzers

Zeta potential from electrophoretic mobility, often with particle size.

  • DynaPro ZetaStar
  • Mobius

4Where the results go next.

Connection guides

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Waters Wyatt instruments.