1How the results reach Seal.
In the laboratory
SCION Instruments gas chromatographs
- ClaritySaves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf)
- Chromeleon CDSSaves report exports selected in the installed Chromeleon version
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and injection
- Retention time
- Peak area
- Amount
- Original file, kept
Results from the SCION Instruments gas chromatographs come from Clarity or Chromeleon CDS.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in Clarity or Chromeleon CDS: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- ClarityDataApex
- 4 models: gas chromatographs. Saves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf).
- Chromeleon CDSThermo Fisher Scientific
- 2 models: gas chromatographs. Saves report exports selected in the installed Chromeleon version.
3The SCION Instruments models.
These are SCION Instruments instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Gas chromatographs
A chromatogram for each injection, integrated into peaks with retention times, areas and amounts.
- SCION 436 GC
- SCION 456 GC
- SCION 8300 GC
- SCION 8500 GC
- Varian / Bruker / SCION 430-GC
- Varian / Bruker / SCION 450-GC
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Scientific data →
Keep instrument files and metadata connected to laboratory work.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your SCION Instruments instruments.