1How the results reach Seal.
In the laboratory
SCIEX LC-MS systems
- SCIEX OS
- AnalystSaves Analyst Results Table text exports
- Analyst TF
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and injection
- Compound
- Mass
- Amount
- Original file, kept
Results from the SCIEX LC-MS systems come from SCIEX OS, Analyst or Analyst TF.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in SCIEX OS, Analyst or Analyst TF: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- SCIEX OS
- 14 models: LC-MS systems.
- Analyst
- 9 models: LC-MS systems. Saves Analyst Results Table text exports.
- Analyst TF
- 3 models: LC-MS systems.
- 32 Karat
- 1 model: capillary electrophoresis system. Saves electropherograms as ASCII or AIA (.cdf) files.
- Biologics Explorer software
- 1 model: capillary electrophoresis system.
- BioPhase software
- 1 model: capillary electrophoresis system. Saves BioPhase analysis reports and result exports available in the installed analysis software.
- EmpowerWaters
- 1 model: capillary electrophoresis system. Saves ASCII raw-data exports (.arw) and separately configured result reports.
3The SCIEX models.
These are SCIEX instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
LC-MS systems
Chromatograms with mass spectra, processed into amounts of target compounds or the masses and identities of what was found.
- 3200 QTRAP
- 4000 QTRAP
- API 2000
- API 3000
- API 3200
- API 4000
- API 5000
- Citrine
- Echo MS+
- novus V55
- QTRAP 4500
- QTRAP 5500
Show all 26 models
- QTRAP 6500+
- SCIEX 4500MD
- SCIEX 7500+
- Triple Quad 3500
- Triple Quad 4500
- Triple Quad 5500
- Triple Quad 6500+
- TripleTOF 4600
- TripleTOF 5600
- TripleTOF 6600
- X500B QTOF
- X500R QTOF
- ZenoTOF 7600+
- ZenoTOF 8600
Capillary electrophoresis systems
An electropherogram for each sample, integrated into peaks for size, charge variants or purity.
- BioPhase 8800
- CESI 8000 Plus
- Intabio ZT
- P/ACE MDQ
- P/ACE MDQ Plus
- PA 800 Plus Pharmaceutical Analysis System
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- Scientific data →
Keep instrument files and metadata connected to laboratory work.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your SCIEX instruments.