Seal Edge collects the files Rigaku software saves and sends each original to Seal, linked to its sample, method and run.

Rigaku instruments to SealInstrument export

Seal reads
Exports from ZSX Guidance, Simultix software and ZSX software
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Rigaku Raman spectrometers

  • CQLSaves SPC, RRB, PDF and TXT files over USB-C or Wi-Fi

Export folder

Where the instrument’s files are saved or copied

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Sample and measurement

  • Spectrum
  • Library match
  • Result
  • Original file, kept
How a result from the Rigaku Raman spectrometers reaches Seal.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay with the instrument and its software: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

ZSX Guidance
2 models: XRF spectrometers.
Simultix software
1 model: XRF spectrometer.
ZSX software
1 model: XRF spectrometer.

Saved by the instrument

CQL
3 models: Raman spectrometers. Each saves SPC, RRB, PDF and TXT files over USB-C or Wi-Fi.

3The Rigaku models.

These are Rigaku instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

XRF spectrometers

Element contents of a solid or liquid sample, from the X-ray fluorescence it emits.

  • Simultix 15
  • Supermini200
  • ZSX Primus 400
  • ZSX Primus III NEXT
  • ZSX Primus IV

Raman spectrometers

A Raman spectrum, with an identity or a concentration where a library or model is applied.

  • CQL Gen-ID
  • CQL Max-ID
  • CQL Narc-ID
  • Progeny