1How the results reach Seal.
In the laboratory
Rigaku Raman spectrometers
- CQLSaves SPC, RRB, PDF and TXT files over USB-C or Wi-Fi
Export folder
Where the instrument’s files are saved or copied
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and measurement
- Spectrum
- Library match
- Result
- Original file, kept
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay with the instrument and its software: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- ZSX Guidance
- 2 models: XRF spectrometers.
- Simultix software
- 1 model: XRF spectrometer.
- ZSX software
- 1 model: XRF spectrometer.
Saved by the instrument
- CQL
- 3 models: Raman spectrometers. Each saves SPC, RRB, PDF and TXT files over USB-C or Wi-Fi.
3The Rigaku models.
These are Rigaku instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
XRF spectrometers
Element contents of a solid or liquid sample, from the X-ray fluorescence it emits.
- Simultix 15
- Supermini200
- ZSX Primus 400
- ZSX Primus III NEXT
- ZSX Primus IV
Raman spectrometers
A Raman spectrum, with an identity or a concentration where a library or model is applied.
- CQL Gen-ID
- CQL Max-ID
- CQL Narc-ID
- Progeny
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Pharmaceutical QC →
Coordinate laboratory work with the batches waiting for results.
- Raw material release →
Connect receipt, sampling and testing before material use.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Rigaku instruments.