Seal Edge collects the files Postnova Analytics software saves and sends each original to Seal, linked to its sample, method and run.

Postnova Analytics instruments to SealInstrument export

Seal reads
Exports from NovaFFF Suite and NovaDmax DLS Software
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Postnova Analytics PN3621 MALS Detector and PN3712 Online DLS

  • NovaDmax DLS SoftwareSaves ASCII and CSV exports

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Sample and measurement

  • Z-average
  • PDI
  • Molar mass
  • Original file, kept
How a result from the Postnova Analytics PN3621 MALS Detector and PN3712 Online DLS reaches Seal.

Results from the Postnova Analytics PN3621 MALS Detector and PN3712 Online DLS come from NovaDmax DLS Software.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in NovaDmax DLS Software: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

NovaFFF Suite
3 models: field-flow fractionation systems.
NovaDmax DLS Software
1 model: light scattering instrument. Saves ASCII and CSV exports.

3The Postnova Analytics models.

These are Postnova Analytics instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Field-flow fractionation systems

Separates particles or molecules by size; the results come from its detectors, often light scattering.

  • AF2000 MultiFlow FFF
  • CF2000 Centri FFF
  • EAF2000 Electrical AF4

Light scattering instruments

Size and polydispersity from dynamic light scattering, or molar mass from static and multi-angle light scattering.

  • PN3621 MALS Detector
  • PN3712 Online DLS

LC detectors

The detector’s signal over time is the chromatogram; the chromatography data system integrates its peaks into retention times, areas and amounts.

  • PN3150 RI Detector

4Where the results go next.

Connection guides

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Postnova Analytics instruments.

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.