1How the results reach Seal.
In the laboratory
Ocean Optics UV-Vis spectrophotometers
- OceanViewSaves processed data as ASCII text files
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and measurement
- Wavelength
- Absorbance
- Concentration
- Original file, kept
Results from the Ocean Optics UV-Vis spectrophotometers come from OceanView.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in OceanView: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- OceanView
- 9 models: UV-Vis spectrophotometers and NIR spectrometers. Saves processed data as ASCII text files.
3The Ocean Optics models.
These are Ocean Optics instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
UV-Vis spectrophotometers
Absorbance at set wavelengths or across a spectrum, converted to concentration where a method applies.
- HR2
- HR4
- HR6
- Ocean HDX
- SR2
- SR4
- SR6
Raman spectrometers
A Raman spectrum, with an identity or a concentration where a library or model is applied.
- NIRQuest+1064 Raman
- QE Pro Raman
NIR spectrometers
A near-infrared spectrum, with an identity or a content where a model is applied.
- Flame-NIR+
Other
- QE Pro
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Pharmaceutical QC →
Coordinate laboratory work with the batches waiting for results.
- Raw material release →
Connect receipt, sampling and testing before material use.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Ocean Optics instruments.