1How the results reach Seal.
In the laboratory
Metrohm ion chromatographs
- MagIC NetSaves CSV, XML, SLK, AIA and TXT exports
- IC NetSaves chromatograms as .chw files, with text and Excel reports
- OMNIS Software
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and injection
- Ion
- Retention time
- Concentration
- Original file, kept
Results from the Metrohm ion chromatographs come from MagIC Net, IC Net or OMNIS Software.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in MagIC Net, IC Net or OMNIS Software: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- MagIC Net
- 21 models: LC detectors, ion chromatographs and LC autosamplers. Saves CSV, XML, SLK, AIA and TXT exports.
- OMNIS Software
- 15 models: NIR spectrometers, titrators, ion chromatographs, Karl Fischer titrators, sample changers and LC autosamplers.
- tiamo
- 15 models: titrators, Karl Fischer titrators and sample changers.
- IC Net
- 5 models: ion chromatographs, LC detectors and LC autosamplers. Saves chromatograms as .chw files, with text and Excel reports.
- BWSpec
- 3 models: Raman spectrometers.
- TID21
- 2 models: Raman spectrometers.
- Vision
- 2 models: Raman spectrometers.
- MIRA Cal DS
- 1 model: Raman spectrometer.
- MIRA Cal P
- 1 model: Raman spectrometer.
- NID
- 1 model: Raman spectrometer.
- SpecSuite
- 1 model: Raman spectrometer.
Saved by the instrument
- Multiparameter meters, conductivity meters and pH meters
- 4 models. Each saves results as CSV to a PC over USB.
- 915 KF Ti-Touch, 916 Ti-Touch and 917 Coulometer
- 3 models: Karl Fischer titrators and titrators. Each saves PDF reports to a USB drive or the network.
- Eco Coulometer
- 1 model: Karl Fischer titrator. Saves PDF reports to a USB drive.
- Eco Titrator
- 1 model: titrator. Saves PDF reports and results to a USB drive.
3The Metrohm models.
These are Metrohm instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Ion chromatographs
A conductivity chromatogram for each injection, integrated into anion or cation concentrations.
- 733 IC Separation Center
- 761 Compact IC
- 761 SD Compact IC
- 850 Professional IC
- 861 Advanced Compact IC
- 881 Compact IC pro
- 882 Compact IC plus
- 883 Basic IC plus
- 930 Compact IC Flex
- 940 Professional IC Vario
- 2060 IC Process Analyzer
- Eco IC
- OMNIS IC L Module
- OMNIS IC M Module
- OMNIS IC S Module
Raman spectrometers
A Raman spectrum, with an identity or a concentration where a library or model is applied.
- 2060 Raman Analyzer
- 2060 RISE
- i-Raman NxG
- i-Raman Plus 532
- i-Raman Plus 785HR
- i-Raman Plus 785S
- MIRA P
- MIRA XTR
- NanoRam
- NanoRam-1064
- PTRam Analyzer
- TacticID Mobile
- TacticID-1064 ST
Titrators
The titrant volume to each endpoint and the content calculated from it, with the titration curve.
- 855 Robotic Titrosampler
- 888 Titrando
- 902 Titrando
- 904 Titrando
- 905 Titrando
- 906 Titrando
- 907 Titrando
- 916 Ti-Touch
- Eco Titrator
- OMNIS Advanced Titrator
- OMNIS Basic Titrator
- OMNIS Professional Titrator
LC detectors
The detector’s signal over time is the chromatogram; the chromatography data system integrates its peaks into retention times, areas and amounts.
- 819 Advanced IC Detector
- 871 Advanced Bioscan
- 887 Professional UV/VIS Detector
- 896 Professional Detector – Amperometry
- 896 Professional Detector – Conductivity & Amperometry
- 944 Professional UV/VIS Detector Vario
- 945 Professional Detector Vario – Amperometry
- 945 Professional Detector Vario – Conductivity
- 947 Professional UV/VIS Detector Vario
- IC Amperometric Detector
- IC Conductivity Detector
Karl Fischer titrators
Water content for each sample, from the titrant or charge needed to reach the endpoint.
- 851 Titrando
- 852 Titrando
- 890 Titrando
- 901 Titrando
- 915 KF Ti-Touch
- 917 Coulometer
- Eco Coulometer
- OMNIS Coulometer
- OMNIS Titrator KF
Sample changers
Moves each sample to the titrator or analyser in turn; the results come from that instrument.
- 810 Sample Processor
- 814 USB Sample Processor
- 815 Robotic USB Sample Processor XL
- 874 Oven Sample Processor
- 885 Compact Oven Sample Changer
- OMNIS Sample Robot
- OMNIS Sample Robot Oven
LC autosamplers
Which vial and volume each injection took, recorded with its chromatogram so each result keeps its sample.
- 838 Advanced IC Sample Processor
- 858 Professional Sample Processor
- 863 Compact IC Autosampler
- 889 IC Sample Center
- 919 IC Autosampler plus
- OMNIS IC Autosampler Module
NIR spectrometers
A near-infrared spectrum, with an identity or a content where a model is applied.
- 2060 The NIR Analyzer
- OMNIS NIR Analyzer Liquid
- OMNIS NIR Analyzer Liquid/Solid
- OMNIS NIR Analyzer Solid
Multiparameter meters
pH, conductivity, dissolved oxygen or other readings from the probes connected.
- 914 pH/Conductometer
- 914 pH/DO/Conductometer
Column ovens
The column temperature, set in the method and recorded with each injection.
- 943 Professional Thermostat Vario
Conductivity meters
Conductivity, corrected to a reference temperature.
- 912 Conductometer
pH meters
pH with temperature, and the calibration slope and offset it was measured against.
- 913 pH Meter
Other
- 860 KF Thermoprep
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Scientific data →
Keep instrument files and metadata connected to laboratory work.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- Pharmaceutical QC →
Coordinate laboratory work with the batches waiting for results.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Metrohm instruments.