1How the results reach Seal.
In the laboratory
MBV AG air samplers
- MAS-100 Iso Communication & Calibration software
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Location and sample
- Air volume
- Location
- Colonies
- Original file, kept
Results from the MBV AG air samplers come from MAS-100 Iso Communication & Calibration software.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in MAS-100 Iso Communication & Calibration software: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- MAS-100 Iso Communication & Calibration software
- 2 models: air samplers.
- PlairGrid Software
- 1 model: microbial detection system.
Saved by the instrument
- MAS-100 Sirius
- 1 model: air sampler. Saves tamper-proof XML exports.
3The MBV AG models.
These are MBV AG instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Air samplers
The volume of air drawn onto each plate, with its location and time; the colony count is read after incubation.
- MAS-100 Atmos
- MAS-100 Iso MH
- MAS-100 Iso NT
- MAS-100 Libra
- MAS-100 NT
- MAS-100 Sirius
- MAS-100 VF
Microbial detection systems
- Rapid-C+
4Where the results go next.
Blueprints
- Environmental monitoring →
Link environmental results to locations, operations and investigations.
- Microbiology laboratory →
Track plates, organisms and results back to samples and batches.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your MBV AG instruments.