1How the results reach Seal.
In the laboratory
Malvern Panalytical particle size analyzers
- Mastersizer Xplorer
- NanoSight NTA softwareSaves NTA CSV analysis results and PDF reports
- RTSizer
- and 4 more
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and measurement
- Dv10
- Dv50
- Dv90
- Original file, kept
Results from the Malvern Panalytical particle size analyzers come from Mastersizer Xplorer, NanoSight NTA software or RTSizer, among 7 applications.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in Mastersizer Xplorer, NanoSight NTA software or RTSizer: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- Zetasizer software
- 9 models: light scattering instruments and zeta potential analyzers. Saves .dts measurement files.
- Mastersizer Xplorer
- 5 models: particle size analyzers.
- OmniSEC
- 4 models: light scattering instruments and LC detectors.
- NanoSight NTA software
- 3 models: particle size analyzers. Saves NTA CSV analysis results and PDF reports.
- RTSizer
- 3 models: particle size analyzers.
- ZS Xplorer
- 3 models: light scattering instruments. Saves CSV parameter and statistics tables from ZS Xplorer Analyze workspaces.
- MicroCal PEAQ-DSC software
- 2 models: DSC. Saves PEAQ-DSC CSV exports of raw, buffer-subtracted or fitted curves.
- OMNISEC software
- 2 models: HPLC / UHPLC systems and light scattering instruments.
- PEAQ-ITC analysis software
- 2 models: calorimeters. Saves PEAQ-ITC analysis exports and injection tables.
- SuperQ
- 2 models: XRF spectrometers.
- Morphologi software
- 1 model: particle size analyzer.
- NS Xplorer
- 1 model: particle size analyzer.
- SAS Software
- 1 model: particle size analyzer.
- Spraytec software
- 1 model: particle size analyzer.
- ZS Discover
- 1 model: light scattering instrument.
3The Malvern Panalytical models.
These are Malvern Panalytical instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Particle size analyzers
A particle size distribution with its summary values, such as Dv50 or a mean size.
- Archimedes
- Insitec 2000
- Insitec Dry
- Insitec Spray
- Insitec Wet
- Mastersizer 2000
- Mastersizer 2000E
- Mastersizer 3000
- Mastersizer 3000+ Lab
- Mastersizer 3000+ Pro
- Mastersizer 3000+ Ultra
- Mastersizer 3000E
Show all 26 models
- Mastersizer Micro
- Morphologi 4
- Morphologi 4-ID
- Morphologi G2
- Morphologi G3
- Morphologi G3-ID
- NanoSight LM10
- NanoSight NS300
- NanoSight NS500
- NanoSight Pro
- SAS II
- SediGraph III Plus
- Spraytec
- Spraytec 97 (RTSizer)
Light scattering instruments
Size and polydispersity from dynamic light scattering, or molar mass from static and multi-angle light scattering.
- OMNISEC REVEAL
- Viscotek 270 Dual Detector
- Viscotek 270max
- Viscotek SEC-MALS 20
- Viscotek TDA 305
- Viscotek TDAmax
- Zetasizer APS
- Zetasizer Core
- Zetasizer Helix
- Zetasizer Lab
- Zetasizer Nano S
- Zetasizer Nano S90
- Zetasizer Nano ZS
- Zetasizer Nano ZS90
- Zetasizer Nano ZSE
- Zetasizer Nano ZSP
- Zetasizer Pro
- Zetasizer Ultra
- Zetasizer µV
Calorimeters
Heat measured over time; in titration calorimetry, the heat of each injection fitted to binding affinity, stoichiometry and enthalpy.
- MicroCal Auto-iTC200
- MicroCal iTC200
- MicroCal MCS-ITC
- MicroCal PEAQ-ITC
- MicroCal PEAQ-ITC Automated
- MicroCal VP-ITC
XRF spectrometers
Element contents of a solid or liquid sample, from the X-ray fluorescence it emits.
- Epsilon 1
- Epsilon 4
- Epsilon Xflow
- Epsilon Xline
- Revontium
- Zetium
DSC
Heat flow against temperature, evaluated into transitions such as melting temperature and enthalpy.
- MicroCal PEAQ-DSC
- MicroCal PEAQ-DSC Automated
- MicroCal VP-Capillary DSC
- MicroCal VP-DSC
Zeta potential analyzers
Zeta potential from electrophoretic mobility, often with particle size.
- Zetasizer AT
- Zetasizer Nano Z
- Zetasizer WT
NIR spectrometers
A near-infrared spectrum, with an identity or a content where a model is applied.
- LabSpec 4 Hi-Res
- LabSpec 4 Standard-Res
X-ray diffractometers
A diffraction pattern, used to identify crystalline phases and their proportions.
- Aeris
- Empyrean
HPLC / UHPLC systems
A chromatogram for each injection, integrated into peaks with retention times, areas and amounts, and reported per sample in a sequence.
- OMNISEC RESOLVE
LC detectors
The detector’s signal over time is the chromatogram; the chromatography data system integrates its peaks into retention times, areas and amounts.
- Viscotek RI Detector (VE3580)
Protein stability analyzers
Unfolding and aggregation temperatures, such as Tm and Tagg, from fluorescence or light scattering.
- Zetasizer Core-DSF
Viscometers
Viscosity at the measured shear rate and temperature.
- Viscotek DSV
Other
- Creoptix WAVEdelta
- Creoptix WAVEsystem
- Viscosizer TD
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- Pharmaceutical QC →
Coordinate laboratory work with the batches waiting for results.
- Raw material release →
Connect receipt, sampling and testing before material use.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Malvern Panalytical instruments.