1How the results reach Seal.
In the laboratory
HORIBA Raman spectrometers
- LabSpec 6Saves LabSpec exported spectral data, images and analysis reports
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and measurement
- Spectrum
- Library match
- Result
- Original file, kept
Results from the HORIBA Raman spectrometers come from LabSpec 6.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in LabSpec 6: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- LabSpec 6
- 8 models: Raman spectrometers. Saves LabSpec exported spectral data, images and analysis reports.
- EzSpec
- 3 models: spectrofluorometers.
- DataStation
- 2 models: spectrofluorometers. Saves .das, IBH v4.2 and ASCII files.
- FluorEssence
- 2 models: spectrofluorometers.
- FelixFL
- 1 model: spectrofluorometer.
- HORIBA X-RAY LAB
- 1 model.
- LA-960V2 software
- 1 model: particle size analyzer.
- OpenPlex Software Suite
- 1 model: surface plasmon resonance system.
- ViewSizer software
- 1 model: particle size analyzer.
3The HORIBA models.
These are HORIBA instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Particle size analyzers
A particle size distribution with its summary values, such as Dv50 or a mean size.
- LA-300
- LA-910
- LA-920
- LA-930
- LA-950A
- LA-950N
- LA-950S
- LA-960
- Partica CENTRIFUGE CN-300
- Partica LA-960V2
- Partica LA-970
- Partica LA-1000
- Partica mini LA-350
- ViewSizer 1000
- ViewSizer 3000
Spectrofluorometers
Fluorescence emission and excitation spectra, or intensities at set wavelengths.
- Aqualog
- Aqualog-Next
- DeltaFlex TCSPC
- DeltaPro TCSPC
- Duetta
- Fluorolog-QM
- FluoroMax Plus
- Nanolog
- QM-800
- Veloci BioPharma Analyzer
Raman spectrometers
A Raman spectrum, with an identity or a concentration where a library or model is applied.
- LabRAM Nano
- LabRAM Odyssey
- LabRAM Odyssey Nano
- LabRAM Soleil
- LabRAM Soleil Nano
- MacroRAM
- XploRA Nano
- XploRA PLUS
Light scattering instruments
Size and polydispersity from dynamic light scattering, or molar mass from static and multi-angle light scattering.
- LB-500
- LB-550
- nanoPartica SZ-100-HS2
- nanoPartica SZ-100-S2
- SZ-100
ICP-OES
Element concentrations per sample from emission at chosen wavelengths, with the calibration behind them.
- Ultima Expert
- Ultima Expert LT
Zeta potential analyzers
Zeta potential from electrophoretic mobility, often with particle size.
- nanoPartica SZ-100-HZ2
- nanoPartica SZ-100-Z2
Surface plasmon resonance systems
Sensorgrams of binding over time, fitted to association and dissociation rates and affinity (KD).
- OpenPlex
Other
- XGT-9000
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- Raw material release →
Connect receipt, sampling and testing before material use.
- Pharmaceutical QC →
Coordinate laboratory work with the batches waiting for results.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your HORIBA instruments.