1How the results reach Seal.
In the laboratory
Berthold Technologies luminometers
- WinTermSaves readings straight into Excel
- FB12 Sirius Software
- LightCompassSaves results as Excel exports
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Plate and sample
- Well
- RLU
- Result
- Original file, kept
Results from the Berthold Technologies luminometers come from WinTerm, FB12 Sirius Software or LightCompass.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in WinTerm, FB12 Sirius Software or LightCompass: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- WinTerm
- 8 models: luminometers. Saves readings straight into Excel.
- LightCompass
- 5 models: luminometers and plate readers. Saves results as Excel exports.
- FB12 Sirius Software
- 3 models: luminometers.
- ICE or MikroWin
- 2 models: plate readers. Saves data as Excel, text or CSV files.
- ClarityDataApex
- 4 models: LC detectors. Saves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf).
- Chromeleon CDSThermo Fisher Scientific
- 1 model: LC detector. Saves report exports selected in the installed Chromeleon version.
Saved by the instrument
- Sirius 2 LB 9526
- 1 model: luminometer. Saves CSV, PDF and HTML files to a USB drive.
3The Berthold Technologies models.
These are Berthold Technologies instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Luminometers
Light output (RLU) for each sample or well.
- AutoCliniLumat LB 952
- AutoLumat 2 LB 956
- AutoLumat LB 953
- Automated Luminescence Analyzer LB 950
- AutorackLumat LB 954
- Biolumat LB 9505
- Centro LB 960
- Centro LB 963
- Centro XS
- CentroLIA LB 961
- CentroLIApc LB 962
- CentroPRO LB 962
Show all 27 models
- CliniLumat LB 9502
- FB12
- FB15 Sirius
- Flash n'Glow LB 955
- Junior LB 9509
- Lumat LB 9500
- Lumat LB 9501
- Lumat LB 9507
- Lumat LB 9508
- Lumat LB 9510
- Microlumat LB 96 P
- Microlumat LB 96 V
- MiniLumat LB 9506
- Orion II LB 965
- Sirius 2 LB 9526
Plate readers
A value for each well (absorbance, fluorescence or luminescence), often reduced to concentrations against a standard curve.
- Apollo 1 LB 911
- Apollo 8 LB 912
- Apollo 11 LB 913
- Apollo LB 917
- Mithras LB 940
- Mithras² LB 943
- TriStar 2 LB 942
- Tristar 3
- Tristar 5
- TriStar LB 941
- TriStar² S LB 942
- Twinkle LB 970
LC detectors
The detector’s signal over time is the chromatogram; the chromatography data system integrates its peaks into retention times, areas and amounts.
- FlowStar LB 509
- FlowStar LB 513
- FlowStar LB 514
- HERM LB 500
- LB 507 Radioactivity Monitor
Microplate washers
Runs the wash steps between assay stages; it measures nothing itself, so the result comes from the reader.
- Zoom HT LB 920
- Zoom LB 921
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- Scientific data →
Keep instrument files and metadata connected to laboratory work.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Berthold Technologies instruments.