1How the results reach Seal.
In the laboratory
Advion Interchim Scientific HPLC / UHPLC systems
- ClaritySaves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf)
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and injection
- Retention time
- Peak area
- Amount
- Original file, kept
Results from the Advion Interchim Scientific HPLC / UHPLC systems come from Clarity.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in Clarity: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- Mass Express
- 1 model: LC-MS system.
- ClarityDataApex
- 5 models: HPLC / UHPLC systems, LC autosamplers, column ovens and LC detectors. Saves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf).
3The Advion Interchim Scientific models.
These are Advion Interchim Scientific instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
HPLC / UHPLC systems
A chromatogram for each injection, integrated into peaks with retention times, areas and amounts, and reported per sample in a sequence.
- Avant HPLC
- Avant UHPLC
Column ovens
The column temperature, set in the method and recorded with each injection.
- Avant Column Oven
LC autosamplers
Which vial and volume each injection took, recorded with its chromatogram so each result keeps its sample.
- Avant Autosampler
LC detectors
The detector’s signal over time is the chromatogram; the chromatography data system integrates its peaks into retention times, areas and amounts.
- Avant PDA Detector
LC-MS systems
Chromatograms with mass spectra, processed into amounts of target compounds or the masses and identities of what was found.
- expression CMS
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Scientific data →
Keep instrument files and metadata connected to laboratory work.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Advion Interchim Scientific instruments.