The weight to dispense, from the lot’s assay.

Enter the lot’s assay and its basis, and see the weight to dispense, rounded up to your balance, and the filler to take out.

The master record

kg
kg
kg
%
%

The lot

%
Assay reported
%

Weight to dispense

StepCalculationResult
As-is assay98.7 × (100 − 4.2) ÷ 10094.5546%
Factor100 ÷ 94.55461.05759
To weigh50.00 kg × 100 ÷ 94.5546 = 52.8795 kg, rounded up to the balance’s 0.01 kg52.88 kg
Filler to weigh67.50 kg − (52.88 − 50.00) kg64.62 kg
Check52.88 kg × 94.5546% = 50.0005 kg100.0% of the claim

Where each number comes from.

The as-is assay is the certificate’s assay × (100 − water) ÷ 100 on the anhydrous basis, with loss on drying in place of water on the dried basis, and both water and solvents taken off on the solvent-free basis. The weight is the quantity × 100 ÷ the as-is assay, rounded up to the balance, since 21 CFR 211.101(a) has a batch formulated “with the intent to provide not less than 100 percent of the labeled or established amount of active ingredient”. A salt is weighed as the salt: the quantity × its molecular weight ÷ the base’s.

EMA’s guideline on the finished dosage form asks for the adjustment and its compensating ingredient to be stated in the batch formula, and ICH Q6A prefers a test specific for water. The potency calculation works the same lot, with the cases a dispensing system should pass.

Keep the calculation with the weighing.

In Seal the potency correction keeps its source values and reviewed calculation, recorded with the scan, the weighings and the check at the batch step.