1How the results reach Seal.
In the laboratory
Rudolph Research Analytical refractometers
- J257 and J357Saves data to a USB drive or the network
Export folder
Where the instrument’s files are saved or copied
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and measurement
- Refractive index
- Temperature
- Brix
- Original file, kept
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay with the instrument and its software: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- Purity software
- 2 models: polarimeters.
Saved by the instrument
- J257 and J357
- 2 models: refractometers. Each saves data to a USB drive or the network.
- DDM 2910
- 1 model: density meter. Saves results to a USB drive, its own drive or a network folder.
- DDM 2911 Plus
- 1 model: density meter. Saves results to a USB drive, its own drive or a network server.
3The Rudolph Research Analytical models.
These are Rudolph Research Analytical instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Refractometers
Refractive index at the measuring temperature, and values derived from it such as Brix.
- J257
- J357
- J457
Density meters
Density at the measuring temperature, and values derived from it such as specific gravity or concentration.
- DDM 2910
- DDM 2911 Plus
Polarimeters
Optical rotation and specific rotation at the measured wavelength and temperature.
- Autopol IIZ
- Autopol IZ
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Pharmaceutical QC →
Coordinate laboratory work with the batches waiting for results.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Rudolph Research Analytical instruments.