Skip to main content

Promega instruments in Seal

Seal Edge collects the files Promega software saves and sends each original to Seal, linked to its sample, method and run.

Illustration of a seal beside a Promega GloMax Explorer plate reader.

Promega instruments to SealInstrument export

Seal reads
Exports from GloMax Discover Software, GloMax Explorer Software and 5 more
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Promega plate readers

  • GloMax Discover SoftwareSaves results as CSV, XLSX and PDF, with .raw result files
  • GloMax Explorer SoftwareSaves results as CSV, XLSX and PDF, with .raw result files
  • Instinct

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Plate and sample

  • Well
  • Reading
  • Concentration
  • Original file, kept
How a result from the Promega plate readers reaches Seal.

Results from the Promega plate readers come from GloMax Discover Software, GloMax Explorer Software or Instinct.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in GloMax Discover Software, GloMax Explorer Software or Instinct: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

GloMax Discover Software
1 model: plate reader. Saves results as CSV, XLSX and PDF, with .raw result files.
GloMax Explorer Software
1 model: plate reader. Saves results as CSV, XLSX and PDF, with .raw result files.
GloMax Galaxy Control Software
1 model: imaging system. Saves images as TIFF files.
GloMax Navigator Software
1 model: luminometer. Saves results as CSV, XLSX and PDF, with .raw result files.
GloMax Spreadsheet Interface Software
1 model: luminometer. Saves data to an Excel spreadsheet.
Instinct
1 model: plate reader.
Quantus Software
1 model: fluorometer. Saves results to Microsoft Excel.

3The Promega models.

These are Promega instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Plate readers

A value for each well (absorbance, fluorescence or luminescence), often reduced to concentrations against a standard curve.

Luminometers

Light output (RLU) for each sample or well.

  • GloMax 20/20
  • GloMax Navigator

Fluorometers

Fluorescence readings converted to concentration against standards.

  • Quantus Fluorometer

Imaging systems

Images with their acquisition settings, and measurements where analysis software takes them.

  • GloMax Galaxy

4Where the results go next.

Connection guides

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Promega instruments.

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.