Seal Edge collects the files NanoTemper Technologies software saves and sends each original to Seal, linked to its sample, method and run.

Illustration of a seal beside a NanoTemper Prometheus Panta.

NanoTemper Technologies instruments to SealInstrument export

Seal reads
Exports from MO.Control, DI.Control and 3 more
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

NanoTemper Technologies molecular interaction analyzers

  • MO.ControlSaves MO.Control reports and MO.Affinity Analysis raw-data and analysis exports
  • DI.ControlSaves CSV, XLSX and JSON files
  • MO.Control 2Saves PDF reports and PNG or SVG images

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Interaction and series

  • Ligand
  • Target
  • KD
  • Original file, kept
How a result from the NanoTemper Technologies molecular interaction analyzers reaches Seal.

Results from the NanoTemper Technologies molecular interaction analyzers come from MO.Control, DI.Control or MO.Control 2.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in MO.Control, DI.Control or MO.Control 2: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

DI.Control
2 models: molecular interaction analyzers. Saves CSV, XLSX and JSON files.
MO.Control 2
2 models: molecular interaction analyzers. Saves PDF reports and PNG or SVG images.
PR.ThermControl
2 models: protein stability analyzers.
PR.Panta Control
1 model: protein stability analyzer. Saves JSON data files.

Saved by the instrument

Tycho NT.6
1 model: protein stability analyzer. Saves a ZIP per measurement, with XLSX data, raw data and images, to a USB drive.

3The NanoTemper Technologies models.

These are NanoTemper Technologies instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Molecular interaction analyzers

Binding curves across a dilution series, fitted to an affinity (KD).

  • Dianthus
  • Dianthus NT.23
  • Dianthus uHTS
  • Monolith
  • Monolith NT.115
  • Monolith NT.115 LabelFree
  • Monolith NT.115 Pico
  • Monolith X

Protein stability analyzers

Unfolding and aggregation temperatures, such as Tm and Tagg, from fluorescence or light scattering.

4Where the results go next.

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your NanoTemper Technologies instruments.

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.