1How the results reach Seal.
In the laboratory
Illumina sequencers
- HiSeq Control Software (HCS)
- NextSeq Control Software (NCS)
- MiSeq i100 Control Software
- and 8 more
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Run and library
- Reads
- Q30
- Yield
- Original file, kept
Results from the Illumina sequencers come from HiSeq Control Software (HCS), NextSeq Control Software (NCS) or MiSeq i100 Control Software, among 11 applications.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in HiSeq Control Software (HCS), NextSeq Control Software (NCS) or MiSeq i100 Control Software: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- HiSeq Control Software (HCS)
- 6 models: sequencers.
- NextSeq Control Software (NCS)
- 3 models: sequencers.
- MiSeq i100 Control Software
- 2 models: sequencers.
- NextSeq 1000/2000 Control Software
- 2 models: sequencers. Saves run folders of CBCL base-call and InterOp files to a network folder.
- NovaSeq X Series Control Software
- 2 models: sequencers. Saves BCL data to a network or cloud location.
- iScan Control Software (iCS)
- 1 model.
- iSeq 100 Control Software
- 1 model: sequencer.
- MiniSeq Control Software (MNCS)
- 1 model: sequencer.
- MiSeq Control Software (MCS)
- 1 model: sequencer.
- MiSeq Operating Software (MOS)
- 1 model: sequencer.
- NovaSeq 6000 Control Software (NVCS)
- 1 model: sequencer. Saves CBCL base-call, filter and InterOp files.
- NovaSeq 6000Dx Operating Software (NVOS)
- 1 model: sequencer.
3The Illumina models.
These are Illumina instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Sequencers
Base calls with quality scores for each run, demultiplexed into reads for each sample.
- HiSeq 1000
- HiSeq 1500
- HiSeq 2000
- HiSeq 2500
- HiSeq X Five
- HiSeq X Ten
- iSeq 100
- MiniSeq
- MiSeq
- MiSeq i100
- MiSeq i100 Plus
- MiSeqDx
Show all 21 models
- NextSeq 500
- NextSeq 550
- NextSeq 550Dx
- NextSeq 1000
- NextSeq 2000
- NovaSeq 6000
- NovaSeq 6000Dx
- NovaSeq X
- NovaSeq X Plus
Other
- iScan System
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Illumina instruments.