Seal Edge collects the files Illumina software saves and sends each original to Seal, linked to its sample, method and run.

Illumina instruments to SealInstrument export

Seal reads
Exports from HiSeq Control Software (HCS), NextSeq Control Software (NCS) and 10 more
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Illumina sequencers

  • HiSeq Control Software (HCS)
  • NextSeq Control Software (NCS)
  • MiSeq i100 Control Software
  • and 8 more

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Run and library

  • Reads
  • Q30
  • Yield
  • Original file, kept
How a result from the Illumina sequencers reaches Seal.

Results from the Illumina sequencers come from HiSeq Control Software (HCS), NextSeq Control Software (NCS) or MiSeq i100 Control Software, among 11 applications.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in HiSeq Control Software (HCS), NextSeq Control Software (NCS) or MiSeq i100 Control Software: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

HiSeq Control Software (HCS)
6 models: sequencers.
NextSeq Control Software (NCS)
3 models: sequencers.
MiSeq i100 Control Software
2 models: sequencers.
NextSeq 1000/2000 Control Software
2 models: sequencers. Saves run folders of CBCL base-call and InterOp files to a network folder.
NovaSeq X Series Control Software
2 models: sequencers. Saves BCL data to a network or cloud location.
iScan Control Software (iCS)
1 model.
iSeq 100 Control Software
1 model: sequencer.
MiniSeq Control Software (MNCS)
1 model: sequencer.
MiSeq Control Software (MCS)
1 model: sequencer.
MiSeq Operating Software (MOS)
1 model: sequencer.
NovaSeq 6000 Control Software (NVCS)
1 model: sequencer. Saves CBCL base-call, filter and InterOp files.
NovaSeq 6000Dx Operating Software (NVOS)
1 model: sequencer.

3The Illumina models.

These are Illumina instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Sequencers

Base calls with quality scores for each run, demultiplexed into reads for each sample.

  • HiSeq 1000
  • HiSeq 1500
  • HiSeq 2000
  • HiSeq 2500
  • HiSeq X Five
  • HiSeq X Ten
  • iSeq 100
  • MiniSeq
  • MiSeq
  • MiSeq i100
  • MiSeq i100 Plus
  • MiSeqDx
  • Show all 21 models
  • NextSeq 500
  • NextSeq 550
  • NextSeq 550Dx
  • NextSeq 1000
  • NextSeq 2000
  • NovaSeq 6000
  • NovaSeq 6000Dx
  • NovaSeq X
  • NovaSeq X Plus

Other

  • iScan System

4Where the results go next.

Connection guides

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Illumina instruments.

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.