Seal Edge collects the files Evident software saves and sends each original to Seal, linked to its sample, method and run.

Evident instruments to SealInstrument export

Seal reads
Exports from cellSens, cellSens Dimension and scanR acquisition software
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Evident imaging systems

  • cellSens
  • cellSens Dimension

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Sample and image

  • Image
  • Measurement
  • Settings
  • Original file, kept
How a result from the Evident imaging systems reaches Seal.

Results from the Evident imaging systems come from cellSens or cellSens Dimension.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in cellSens or cellSens Dimension: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

cellSens
1 model: imaging system.
cellSens Dimension
1 model: imaging system.
scanR acquisition software
1 model: high-content imaging system.

3The Evident models.

These are Evident instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Imaging systems

Images with their acquisition settings, and measurements where analysis software takes them.

  • CKX53 Inverted Microscope
  • IXplore IX73 Standard
  • IXplore IX85

High-content imaging systems

Images of each well and field, analysed into measurements per cell or per well.

  • scanR High-Content Screening Station

4Where the results go next.

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Evident instruments.

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.