1How the results reach Seal.
In the laboratory
ERWEKA tablet testers
- MC.NET
- ERWEKA Export ManagerSaves PDF or XML test reports to the lab network
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Test and tablet
- Hardness
- Thickness
- Weight
- Original file, kept
Results from the ERWEKA tablet testers come from MC.NET or ERWEKA Export Manager.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in MC.NET or ERWEKA Export Manager: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- MC.NET
- 4 models: tablet testers.
- Disso.NET 4
- 2 models: dissolution testers. Saves PDF reports, with results in XLS or XML.
- ERWEKA Export Manager
- 2 models: tablet testers. Saves PDF or XML test reports to the lab network.
- Disso.NET USP 4
- 1 model: dissolution tester. Saves PDF reports, with results in formats such as XML.
Saved by the instrument
- Easycheck
- 1 model: tablet tester. Saves results as CSV or XML over the network.
3The ERWEKA models.
These are ERWEKA instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Tablet testers
Hardness, thickness, diameter and weight for each tablet, with the batch statistics.
- Easycheck
- MultiCheck 6
- TAR II
- TBH 125
- TBH 325
- TBH 425
- TBH II
Dissolution testers
The test conditions for each vessel (time, temperature and speed) and the samples drawn; the percentage dissolved comes from their analysis.
- DFZ II
- DT 950
- DT 9510
- DT Light
Disintegration testers
The disintegration time for each basket position.
- ZT 120 Light
- ZT 320
- ZT 730
Other
- SBT 2
- ST 35
- SVM II
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Oral solid dose →
Connect dispensing, processing, packaging and material reconciliation.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your ERWEKA instruments.