Seal Edge collects the files BUCHI software saves and sends each original to Seal, linked to its sample, method and run.

BUCHI instruments to SealInstrument export

Seal reads
Exports from MeltingPoint Monitor
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

BUCHI Melting Point M-560 and Melting Point M-565

  • MeltingPoint MonitorSaves results and methods as XML

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Sample and measurement

  • Onset
  • Clear point
  • Ramp rate
  • Original file, kept
How a result from the BUCHI Melting Point M-560 and Melting Point M-565 reaches Seal.

Results from the BUCHI Melting Point M-560 and Melting Point M-565 come from MeltingPoint Monitor.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in MeltingPoint Monitor: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

MeltingPoint Monitor
1 model: melting point apparatus. Saves results and methods as XML.

Saved by the instrument

Melting Point M-560
1 model: melting point apparatus. Saves XML to a PC over its serial port.

3The BUCHI models.

These are BUCHI instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Melting point apparatus

The melting point or range of each sample.

  • Melting Point M-560
  • Melting Point M-565