1How the results reach Seal.
In the laboratory
BMG LABTECH plate readers
- Reader Control and MARSSaves MARS Excel or ASCII result exports
- SMART Control and MARS
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Plate and sample
- Well
- Reading
- Concentration
- Original file, kept
Results from the BMG LABTECH plate readers come from Reader Control and MARS or SMART Control and MARS.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in Reader Control and MARS or SMART Control and MARS: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- Reader Control and MARS
- 10 models: plate readers and luminometers. Saves MARS Excel or ASCII result exports.
- SMART Control and MARS
- 1 model: plate reader.
3The BMG LABTECH models.
These are BMG LABTECH instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Plate readers
A value for each well (absorbance, fluorescence or luminescence), often reduced to concentrations against a standard curve.
- CLARIOstar
- CLARIOstar Plus
- FLUOstar Galaxy
- FLUOstar Omega
- FLUOstar OPTIMA
- NEPHELOstar
- NEPHELOstar Plus
- NOVOstar
- PHERAstar FS
- PHERAstar FSX
- PHERAstar Plus
- POLARstar Galaxy
- POLARstar Omega
- POLARstar OPTIMA
- RUBYstar
- SPECTROstar Nano
- SPECTROstar Omega
- VANTAstar
Luminometers
Light output (RLU) for each sample or well.
- LUMIstar Galaxy
- LUMIstar Omega
- LUMIstar OPTIMA
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your BMG LABTECH instruments.