1How the results reach Seal.
In the laboratory
Applied Photophysics SUPR-CM and SUPR-DSF
- SUPR-Suite
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and scan
- Tm
- Tagg
- Onset
- Original file, kept
Results from the Applied Photophysics SUPR-CM and SUPR-DSF come from SUPR-Suite.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in SUPR-Suite: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- HOS Comparison Software
- 1 model: circular dichroism spectrometer.
- ProData
- 1 model.
- SUPR-Suite
- 1 model: protein stability analyzer.
3The Applied Photophysics models.
These are Applied Photophysics instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Circular dichroism spectrometers
A circular dichroism spectrum, read for secondary structure, or followed against temperature for stability.
- Chirascan
- Chirascan Q100
- Chirascan V100
- Chirascan VX
Protein stability analyzers
Unfolding and aggregation temperatures, such as Tm and Tagg, from fluorescence or light scattering.
- SUPR-CM
- SUPR-DSF
Other
- SX20
- SX20-LED
4Where the results go next.
Blueprints
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- QC laboratory →
Follow samples from receipt through testing and result review.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Applied Photophysics instruments.