1How the results reach Seal.
In the laboratory
Anton Paar density meters
- AP ConnectSaves CSV, XLSX, PDF and JSON exports
- EasyDens app
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and measurement
- Density
- Temperature
- Concentration
- Original file, kept
Results from the Anton Paar density meters come from AP Connect or EasyDens app.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in AP Connect or EasyDens app: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- AP Connect
- 33 models: density meters, refractometers, viscometers and polarimeters. Saves CSV, XLSX, PDF and JSON exports.
- Kalliope
- 11 models: particle size analyzers and light scattering instruments. Saves Kalliope exported measurement results and configurable reports.
- RheoCompass
- 9 models: rheometers.
- V-Collect
- 3 models: viscometers. Saves data as an .xls file.
- SurPASS 3 software
- 2 models: zeta potential analyzers.
- EasyDens app
- 1 model: density meter.
Saved by the instrument
- DMA
- 3 models: density meters. Each saves CSV or TXT files to a PC over Bluetooth.
- MCP
- 2 models: polarimeters. Each saves data to a server over Ethernet, automatically.
- SVM
- 2 models: viscometers. Each saves data to a PC or USB drive.
- ViscoQC 300
- 1 model: viscometer. Saves PDF and CSV exports.
3The Anton Paar models.
These are Anton Paar instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Density meters
Density at the measuring temperature, and values derived from it such as specific gravity or concentration.
- DMA 35
- DMA 35 Ampere
- DMA 35 Basic
- DMA 35 Ex
- DMA 501
- DMA 502
- DMA 1001
- DMA 1002
- DMA 1102 Petro
- DMA 4002
- DMA 4101
- DMA 4200 M
Show all 22 models
- DMA 4500 M
- DMA 4501
- DMA 5000 M
- DMA 5001
- DMA 5002
- DMA 6002 Sound Velocity
- EasyDens
- Ultrapyc 3000
- Ultrapyc 5000
- Ultrapyc 7000
Refractometers
Refractive index at the measuring temperature, and values derived from it such as Brix.
- Abbemat 3001
- Abbemat 3101
- Abbemat 3201
- Abbemat 5001
- Abbemat 5101
- Abbemat 5201
- Abbemat 7001
- Abbemat 7201
- SmartRef
Rheometers
Viscosity and viscoelastic moduli against shear rate, time or temperature.
- MCR 53
- MCR 73
- MCR 93
- MCR 102e
- MCR 303
- MCR 503
- MCR 703
- MCR 703 Space
- RheolabQC
Viscometers
Viscosity at the measured shear rate and temperature.
- Lovis 2001
- SVM 1001
- SVM 1101
- SVM 2001
- SVM 3001
- SVM 4001
- ViscoQC 100
- ViscoQC 300
Particle size analyzers
A particle size distribution with its summary values, such as Dv50 or a mean size.
- Litesizer DIA 100
- Litesizer DIA 500
- Litesizer DIA 700
- Litesizer DIF 100
- Litesizer DIF 300
- Litesizer DIF 500
Light scattering instruments
Size and polydispersity from dynamic light scattering, or molar mass from static and multi-angle light scattering.
- Litesizer 500
- Litesizer DLS 101
- Litesizer DLS 301
- Litesizer DLS 501
- Litesizer DLS 701
Polarimeters
Optical rotation and specific rotation at the measured wavelength and temperature.
- MCP 100
- MCP 150
- MCP 4100
- MCP 5100
- MCP 5500
Zeta potential analyzers
Zeta potential from electrophoretic mobility, often with particle size.
- SurPASS 3 Eco
- SurPASS 3 Standard
Other
- Ultratap 500
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Pharmaceutical QC →
Coordinate laboratory work with the batches waiting for results.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Anton Paar instruments.