Anton Paar instruments in Seal

Seal IoT collects the files AP Connect, Kalliope and RheoCompass saves and sends them to Seal over outbound HTTPS. Each original file stays with its results, linked to the sample, method and run.

Illustration of a seal following a sample vial to an analytical instrument and its result.

1The Anton Paar models.

These are Anton Paar instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Density meters

  • DMA 35
  • DMA 35 Ampere
  • DMA 35 Basic
  • DMA 35 Ex
  • DMA 501
  • DMA 502
  • DMA 1001
  • DMA 1002
  • DMA 1102 Petro
  • DMA 4002
  • DMA 4101
  • DMA 4200 M
  • DMA 4500 M
  • DMA 4501
  • DMA 5000 M
  • DMA 5001
  • DMA 5002
  • DMA 6002 Sound Velocity
  • EasyDens
  • Ultrapyc 3000
  • Ultrapyc 5000
  • Ultrapyc 7000

Refractometers

  • Abbemat 3001
  • Abbemat 3101
  • Abbemat 3201
  • Abbemat 5001
  • Abbemat 5101
  • Abbemat 5201
  • Abbemat 7001
  • Abbemat 7201
  • SmartRef

Rheometers

  • MCR 53
  • MCR 73
  • MCR 93
  • MCR 102e
  • MCR 303
  • MCR 503
  • MCR 703
  • MCR 703 Space
  • RheolabQC

Viscometers

  • Lovis 2001
  • SVM 1001
  • SVM 1101
  • SVM 2001
  • SVM 3001
  • SVM 4001
  • ViscoQC 100
  • ViscoQC 300

Particle size analyzers

  • Anton Paar Litesizer
  • Litesizer DIA 100
  • Litesizer DIA 500
  • Litesizer DIA 700
  • Litesizer DIF 100
  • Litesizer DIF 300
  • Litesizer DIF 500

Light scattering instruments

  • Litesizer 500
  • Litesizer DLS 101
  • Litesizer DLS 301
  • Litesizer DLS 501
  • Litesizer DLS 701

Polarimeters

  • MCP 100
  • MCP 150
  • MCP 4100
  • MCP 5100
  • MCP 5500

Zeta potential analyzers

  • SurPASS 3 Eco
  • SurPASS 3 Standard

Other

  • Ultratap 500

2How Seal collects the results.

Seal IoT runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. For these instruments that is usually AP Connect, Kalliope and RheoCompass. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the run and sample it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and the vendor’s analysis stay in the instrument software: Seal collects completed results and sends no instructions to the instrument.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

3Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Anton Paar instruments.