ProteinSimple Jess

Instrument Connection

Connect automated Western results to protein expression, identity and comparability studies.

Put this connection to work Set up ProteinSimple Jess in the docs
Illustration of a seal following a sample vial to an analytical instrument and its result.

Automated Western analysis / Data integration

From instrument evidence to connected records.

Connect automated Western results to protein expression, identity and comparability studies. Seal connects the exported evidence to the experiments, samples and review workflows your team already uses.

  1. ExportThe vendor software saves the measurement or evaluated result.
  2. CollectSeal IoT on the site computer uploads the completed file.
  3. MapA Seal Script validates the data and writes your chosen fields.

Instrument acquisition, analysis and control stay in the vendor software. This connection uses the existing Seal file and entity APIs. Configure the collection and mapping for your installed software and export layout; selecting the instrument in the directory does not install a parser or start acquisition.

What evidence can ProteinSimple Jess provide?

Source
Bio-Techne / ProteinSimple Jess
Evidence to collect
Compass for Simple Western result tables and raw trace exports, plus PDF run reports.

Export options depend on the installed software and licences. The ProteinSimple Jess setup guide covers source preparation and collection in Seal.

Compass for Simple Western and Compass for iCE use different data models. The Jess mapping must not reuse Maurice tables based only on the shared Compass name. Treat image lanes, traces and numeric summaries as linked evidence from the same run.

Keep one representative export and its matching instrument report. Record the software version, licensed export options, chosen columns or sheets, and which results the file actually contains. Check the layout after a software or report-template change.

Vendor reference: Bio-Techne Compass for Simple Western user guide: exporting run files. Product pages describe the source software; verify detailed export options against the manual for your installed version.

Choose the records you need.

One sample-capillary analysis with selected target signals or normalized results linked to its run and source files.

These are suggested fields, not a required schema. Reuse your existing sample, experiment, equipment and method references. Preserve complete exports as File content; store selected values as typed fields when people need to filter, compare, calculate or review them.

Suggested field mapping for ProteinSimple Jess
InformationSeal fieldsMapping rule
Run and capillaryReference and textIdentify the capillary within its run, including repeated samples.
Target signalText, number and unitKeep target, channel and peak-area convention together.
NormalizationNumber and referencePreserve the reference used and retain the unnormalized result when required.
Analysis evidenceFile and textLink the result table, trace and revision used for the result.

Context to retain: Run, capillary and sample identity, target and channel, antibody context, loading, peak integration, normalization, molecular-weight convention and analysis revision. A missing, failed or qualified result should stay distinguishable from a valid zero. Require explicit sample identities and reject unexpected layouts before the Script writes results.

Ready to configure the connection?

The platform docs contain the setup steps: prepare the source export, choose your System and template, configure collection, and test a mapping Script against your actual fields.

Follow the ProteinSimple Jess setup guide ↗

Start with one representative export and its matching vendor report. The on-site equipment docs cover IoT installation, credentials and the first upload. The instrument mapping docs explain File content, typed records and ordinary Seal Scripts.

The site computer connects to Seal over outbound HTTPS. A cloud Script cannot read the instrument’s local drive. Collection frequency follows the export workflow: a folder watcher observes saved files and does not request new measurements.

Keep the source files until delivery and mapping are verified. For frequent or large datasets, choose useful summaries or intervals, retain coverage information and measure the intended volume before unattended operation.

Use the evidence in your existing workflow.

Imported records use normal Seal permissions and references. Compare typed results in views and formulas, link the analysis to a procedure, and use @ references to give neil the accessible samples, experiments and source evidence needed for a question.

Compare these Jess target signals across samples, showing normalization references, controls and analysis revisions.

neil can help write the mapping Script from a representative file and the actual fields in your System. Ask for a proposed mapping and a dry run first. Review its sample matching and scientific assumptions before allowing writes. An instrument name alone does not define a file layout or an analysis method.

Define which fields the import owns. Preserve user-entered notes, review decisions and formula-controlled values. Keep source acquisition time, analysis revision and import time separate so later reanalysis remains understandable.

Prove the workflow with representative data.

A useful first acceptance check

Import a run with two targets, a control and repeated samples. Verify raw versus normalized values and rerun mapping after a peak-integration change.

  1. Compare the result, not only the upload. Check the destination sample, selected values, units, qualifiers and linked File against the vendor report.
  2. Replay identical input. Verify the Script recognizes the source identity and revision before creating another result. File-upload calls alone do not prevent duplicate scientific records.
  3. Reprocess the analysis. Export a changed evaluation and check that it retains its prior evidence. Decide explicitly whether this creates a linked analysis or updates allowed fields under your normal review rules.
  4. Interrupt and recover. With disposable data, test a network interruption and restart. Also test failure after upload but before mapping completes. Confirm retained files, visible failures and correct retry behavior for the installed IoT app and Script.

Reconcile the source run or sample list with the imported analyses. A watcher cannot recover measurements the instrument never exported. Retain the checks and their evidence with the configured connection before relying on it for your intended use.

When the result is missing or looks wrong.

No file arrives
Confirm the instrument created a completed export in the watched folder. Check the IoT account’s file access, upload logs, destination System and template permissions.
The File exists, but result fields are empty
Check whether the mapping Script ran and recognized the export. Resolve missing sample identities or fields explicitly; uploading bytes does not populate an analysis automatically.
The values differ from the instrument report
Raw peak area and normalized expression are not interchangeable. Keep target, detection channel and normalization reference explicit, and retain changes to peak integration. Compare the exact export, report and evaluation revision using the field rules above.
Results are repeated or an analysis is missing
Check export selection, source identities and revision matching. Reconcile at the analysis level; a filename or successful network response alone cannot establish complete coverage.